On Guard Home Inspections

Website: http://www.onguardhomeinspections.com
Email: mike@onguardhomeinspections.com
Phone: (919) 934-2983 ยท (919) 649-4153
FAX: (919) 585-4405
On Guard Home Inspections 
216 Norwood Drive 
Clayton, NC 27527 

Inspector: Mike Decker
License: NC # 2308

Associate Inspector: Rebecca Decker
License NC #A-801

Summary Page

On Guard Home Inspections
Residential Property Inspection Report
Client(s): Randy Lacus
Property address: 110 Rosie Drive
Four Oaks, NC 27524
Inspection date: Wednesday, January 02, 2008

This summary page published on 1/2/2008 7:11:12 PM EST

Return to report

NOTICE TO ALL CLIENTS: This report contains technical information that may or may not be readily understandable to the layperson. Therefore, a verbal consultation with the inspector is an integral part of this inspection report. If you were not present during the inspection, please call the office to arrange for your verbal consultation over the phone. This inspection represents the results of a limited visual examination of certain readily accessible systems and components using normal operating controls and openings / access panels. The inspection and report do not address and are not intended to address the possible presence of or danger from any potentially harmful substances and environmental hazards including by not limited to MOLD, Radon Gas, Lead Paint, Asbestos, Urea Formaldehyde, toxic or flammable chemicals and water and airborne hazards. Also excluded are inspections of and report on swimming pools, wells, septic systems, security systems, central vacuum systems, water softeners, sprinkler systems, fire and safety equipment and the presence or absence of rodents, termites and other insects. The scope of this inspection and terms of the relationship between the parties are defined in the Pre-inspection Agreement signed by the parties. The SUMMARY REPORT is provided as an accessory to the Inspection Report. It summarizes the inspectors comments regarding conditions and/or concerns found during the course of the visual examination and does not represent the full inspection and should not be used separate from the inspection report.





Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
MaintainRecommend ongoing maintenance 
EvaluateRecommend further investigation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

3) Exterior: - The front flights of stairs have more than three risers with no handrail installed. This is a safety hazard. A qualified contractor should install graspable handrails that your hand can completely encircle at stairs where missing, and as per standard building practices.

4) Exterior: - Handrail at deck stairs are loose and weak or wobbly. This is a safety hazard. A qualified contractor should make repairs as necessary. For example, installing new fasteners and/or hardware so handrails are securely attached.

5) Exterior: - Gaps larger than four inches were found in one or more guardrails. This is a safety hazard, especially for small children. A qualified contractor should make modifications as necessary so gaps in guardrails do not exceed four inches. For example, installing additional balusters or railing components.

6) Exterior: - Siding is damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs and/or replace siding as necessary to prevent water and vermin intrusion.

7) Exterior: - Minor cracks were found in one or more sections of brick steps. A qualified contractor should evaluate and make repairs as necessary, such as repointing mortar to prevent water intrusion and further deterioration in the future.

8) Exterior: - Rot was found in several deck boards. A qualified contractor should evaluate and repair as necessary. All rotted wood should be replaced.

9) Exterior: - This house does NOT have gutters. This can result in water accumulating around the structure's foundation and crawl space. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should install gutters and downspouts where missing. Also, extensions such as splashblocks or tie-ins to underground drain lines should be installed as necessary to carry rain water away from the house.

10) Exterior: - Siding is incomplete or missing in one or more areas. A qualified contractor should install siding where missing to prevent water and vermin intrusion.

11) Exterior: - The outside faucets are missing handles. Recommend installing handles where missing.

12) Exterior: - The exhaust duct end cap for the dryer is damaged and/or deteriorated. Its purpose is to prevent unconditioned air from entering the house, and keep out birds, rodents and bugs. Blocked ducts can cause fan motors and/or clothes dryers to overheat and may pose a fire hazard. New vent cap(s) should be installed where necessary.

13) Exterior: - Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.

14) Exterior: - The finish on the deck and railing is worn and/or deteriorated. Recommend cleaning and refinishing as necessary.

19) Water heater: - No water supply shut-off valve is visible for the water heater. A shut-off valve allows the supply to the water heater to be turned off when the water heater needs repair or replacement, while allowing the remainder of the plumbing system to be operable (toilets, sinks, etc.). Recommend having a qualified, licensed plumbing contractor determine if a water supply shut-off valve exists, and install one if it is missing.

22) Heating and cooling: - No filter is visible for the heating/cooling system. As a result, unfiltered air will flow through the system, and the heating/cooling equipment life and the indoor air quality may be reduced. Correctly sized filter(s) should be installed. If necessary, guides or retaining devices should be installed or repaired so filter(s) are securely anchored and gaps around edges are minimized.

23) Heating and cooling: - One or more heat and air supply registers are damaged / broken and should be replaced.

24) Heating and cooling: - Insulation for the outside condensing unit's refrigerant lines is damaged, deteriorated and/or missing in one or more areas. This may result in reduced efficiency and increased energy costs. A qualified heating and cooling contractor should replace insulation as necessary.

25) Heating and cooling: - The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.

27) Plumbing and laundry: - The clothes dryer is equipped with a vinyl, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. These types of ducts can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow. This duct should be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. Most clothes dryer manufacturers specify the use of a rigid or corrugated semi-rigid metal duct. For more information on dryer safety issues, see http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

28) Plumbing and laundry: - The inspector was not able to find the main water shut-off valve. The client(s) should consult with the property owner(s) to determine if a shut-off valve exists, find it themselves, or hire a qualified plumber if necessary to find it. If no shut-off valve is found for the structure, then recommend having a qualified plumber install one to more easily allow the water supply to be turned off in the event of an emergency, such as when a supply pipe bursts.

29) Plumbing and laundry: - Plumbing supply lines appear to be made of Polybutylene. Polybutylene is a plastic material used extensively during the 1980s and 1990s that has proven to be more prone to leakage than other types of supply piping systems like copper. Recommend reviewing any disclosure statements if available for comments on leaks in the water supply system.

A class action lawsuit has been filed regarding this material that requires the manufacturers to cover piping systems installed between Jan. 1, 1978 through July 31, 1995. For more information on the class action lawsuit, visit http://www.pbpipe.com/index1.htm , or call the Plumbing Claims Group at (800) 356-3496 for more information.

30) Fireplaces, woodstoves and chimneys: - The fireplace equipped with a gas burner has a damper that can be closed. This is a safety hazard due to the possibility of burner or pilot light exhaust gases entering living spaces. A qualified chimney service contractor should make repairs as necessary so the damper is made permanently open. Typically a bracket or bolt is installed for this purpose.

32) Crawl space: - Evidence of prior water intrusion was found in one or more sections of the crawl space. For example, sediment stains on the vapor barrier or foundation, and/or efflorescence on the foundation. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the crawl space. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the crawl space. The crawl space should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in crawl spaces include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter crawl spaces, but if water must be controlled after it enters the crawl space, then typical repairs include installing trenches, gravity drains and/or sump pump(s) in the crawl space.

  • 33) Crawl space: - No vapor barrier is installed. This is a conducive condition for wood destroying insects and organisms due to the likelihood of water evaporating into the structure from the soil. A qualified contractor should install a vapor barrier.

    35) Kitchen: - The range can tip forward, and no anti-tip bracket appears to be installed. This is a safety hazard since the range may tip forward when weight is applied to the open door, such as when a small child climbs on it, or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free standing ranges since 1985. An anti-tip bracket should be installed to eliminate this safety hazard. For more information, visit http://www.hgtv.com/hgtv/remodeling/article/0,1797,HGTV_3659_2017492,00.html

    36) Kitchen: - The oven bake function appears to be inoperable. The client(s) should ask the property owner(s) about this, and if necessary, a qualified appliance technician should evaluate and repair as necessary.

    37) Kitchen: - The oven broil function appears to be inoperable. The client(s) should ask the property owner(s) about this, and if necessary, a qualified appliance technician should evaluate and repair as necessary.

    38) Kitchen: - The stove top burners are inoperable and two are missing. A qualified appliance technician should evaluate and repair as necessary.

    39) Kitchen: - One or more cabinets and/or drawers are damaged. A qualified contractor should evaluate and repair or replace cabinets and/or components as necessary.

    40) Kitchen: - The oven light is inoperable. Recommend replacing bulb or having repairs made if necessary by a qualified appliance technician.

    41) Bathrooms: - The carpet installed in "wet" areas will let water pass through it. The wooden subfloor beneath may be damaged by water intrusion. A qualified contractor should evaluate, make repairs if necessary, and replace flooring with a waterproof floor such as sheet vinyl in wet areas.

    42) Bathrooms: - Caulk is missing or deteriorated above one or more bathtubs, where the tub surround meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the wall structure.

    43) Bathrooms: - Caulk is missing or deteriorated around the base of one or more bathtub spouts. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall structures.

    44) Bathrooms: - Caulk is missing or deteriorated around one or more shower surrounds. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the wall structure.

    45) Bathrooms: - One or more bathroom light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb and/or consulting with the property owner(s). Repairs or replacement of the light fixture by a qualified electrician may be necessary.

    46) Bathrooms: - One or more toilets have no water supply and could not be fully evaluated. The shut-off valve may be turned off, or repairs may be necessary. The client(s) should ask the property owner(s) about this, and have a qualified plumber evaluate and repair if necessary.

    47) Interior rooms: - An insufficient number of smoke alarms are installed. Additional smoke alarms should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html

    48) Interior rooms: - Screen in one or more windows are missing. The client should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.

    49) Interior rooms: - Squeaking or creaking noises occur when walking on one or more sections of flooring. In most cases, this is only an annoyance rather than a structural problem. Various solutions such as Squeeeeek No More and Counter Snap fasteners exist to correct this. Repairs to eliminate the squeaks or creaks may be more or less difficult depending on the floor covering, and the access to the underside of the subfloor. Recommend having a qualified contractor evaluate and repair as necessary.

    50) Interior rooms: - Water stains were found in the wall beneath the kitchen window. Cause or source of water entry could not be determined. Recommend having a licensed contractor evaluate to isolate the source of water penetration to interior wall and repair or replace window as necessary.

    51) Interior rooms: - The back exterior entrance door is damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.

    52) Interior rooms: - Carpeting in one or more rooms is loose. Recommend having a qualified carpeting installation contractor restretch carpet as necessary.

    53) Interior rooms: - Carpeting in one or more rooms is damaged and/or significantly deteriorated. Recommend replacing carpeting where necessary.

    54) Interior rooms: - Trim is loose in one or more areas. Recommend having a qualified contractor repair trim where needed.

    55) Interior rooms: - Fixtures such as door stops, towel bars and/or toilet paper holders are missing and broken in one or more areas. Recommend having a qualified contractor install fixtures where missing or broken.

    56) Interior rooms: - Several light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb and/or consulting with the property owner(s). Repairs or replacement of the light fixture by a qualified electrician may be necessary.